Overview

Strict enforcement of environmental pollution standards has had a dramatic impact on tank storage of flammable liquids. Rather than expelling vapors into the atmosphere, the trend has been toward the connecting or manifolding of multiple tanks through common piping to a central processing unit. These closed piping systems, or vapor recovery / collection systems, have created unique flammable vapor safety hazards. The piping runs in these vapor recovery systems tend to be longer and more complex. Potential sources of ignition may actually be present within the vapor collection system itself. An ignition within a piping system can result in a flame front that accelerates very rapidly and generates extremely high pressures. A low speed, low pressure confined deflagration can readily transition into a high speed, high pressure confined deflagration and then to a detonation, which is a flame front moving at the speed of sound in the vapor/air mixture. “DETONATION” arresters are specifically designed to stop and extinguish detonations, confined deflagrations and unconfined deflagrations. The limitations that are placed on the location of end-of-line and vent-line / in-line flame arresters with respect to the ignition source do not apply to detonation arresters.


Bi-Directional Overdriven / Unstable
Detonation Flame Arresters

DETONATION FLAME ARRESTERThe Protectoseal Series Nos. 25000 & 26000 Detonation Flame Arresters are specifically designed to withstand and arrest the high velocity and high pressure flame fronts that may develop in long or complex piping runs such as those encountered in vapor recovery or manifolded tank systems. The arresters provide positive protection against flame transmission through piping systems handling chemical vapor mixtures as referenced in the National Electric Code (NEC) Article 500:

DETONATION FLAME ARRESTERThe Protectoseal Series Nos. 35000 & 36000RP Detonation Flame Arresters are specifically designed to withstand and arrest the high velocity and high pressure flame fronts that may develop in long or complex piping runs such as those encountered in vapor recovery or manifolded tank systems. The arresters provide positive protection against flame transmission through piping systems handling chemical vapor mixtures as referenced in the National Electric Code (NEC) Article 500:

Protectoseal Series 25000/26000 Specifications

Protectoseal Series 35000/36000RP Specifications


Bi-Directional Overdriven / Unstable
Detonation Flame Arresters

ATEX / CE /  ISO Approved according to the latest ATEX Directive and ISO Standard 16852

DETONATION FLAME ARRESTERThe Protectoseal Series Nos. 25000E & 35000E Detonation Flame Arresters are specifically designed to withstand and arrest the high velocity and high pressure flame fronts that may develop in long or complex piping runs such as those encountered in vapor recovery or manifolded tank systems. The arresters provide positive protection against flame transmission through piping systems handling chemical vapor mixtures as referenced below:

 

DETONATION FLAME ARRESTERThe Protectoseal Series Nos. 26000E / 36000E Detonation Flame Arresters are specifically designed to withstand and arrest the high velocity and high pressure flame fronts that may develop in long or complex piping runs such as those encountered in vapor recovery or manifolded tank systems. The arresters provide positive protection against flame transmission through piping systems handling chemical vapor mixtures as referenced below:

 

Protectoseal Series 25000E/35000E Specifications

Protectoseal Series 26000E/36000E Specifications